48% vs 8%
Sensitivity for a composite adverse perinatal outcome: FRI red zone vs ACOG Category III
434 consecutive term singleton deliveries at the Medical College of Georgia, Augusta, January to December 2025. FRI was scored from the recorded traces every 20 minutes over the last three hours of labor. Specificity was 93.5% for FRI and 98.1% for Category III (p = 0.052); overall accuracy was 77.4% vs 66.0%. The composite outcome is driven mainly by newborn resuscitation and NICU admission.
- Design:
- Retrospective cohort
- Status:
- Unpublished research: manuscript under revision, not yet peer-reviewed